Experience unmatched power and performance with our state-of-the-art PowerCore 500 kW Inverter. Designed to meet the demands of large-scale renewable energy projects, this high-capacity central solar inverter offers a wide range of features, including maximum efficiency of 98.6% and Euro-eta of 98.2%. With advanced protection mechanisms, smart grid integration, and a user-friendly interface, the PowerCore 500 kW is the ideal solution to optimize energy production and drive your renewable energy initiatives forward.

 

PowerCore 500

Input (DC)

Maximum input power (PPV, max) 

DC voltage range, mpp (UDC, mpp)

Maximum DC voltage (Umax (DC))

Maximum DC current (Imax (DC))

Number of protected DC inputs

Output (AC)

Nominal power (PN(AC)) 

Maximum output power 

Power at cosj = 0.95 3) Nominal AC current (IN(AC)) Nominal output voltage (UN(AC)) 

 

 

Output frequency

Harmonic distortion, current 

Distribution network type 

Efficiency

Maximum 

Euro-eta 

Power consumption

Own consumption in operation

Standby operation consumption

External auxiliary voltage 

Dimensions and weight

Width/Height/Depth, mm (W/H/D)

Weight appr. 

      +/- 10%

     At nominal power

     Inverter side must be IT type

     Without auxiliary power consumption at min UDC

     115 V, 60 Hz optional

    For the smallest number of protected inputs. See the user manual for details.

Environmental limits

Degree of protection

Ambient temp. range (nom. ratings) 

Maximum ambient temperature 

Relative humidity, not condensing

Maximum altitude (above sea level) 

Maximum noise level

Maximum air flow of the inverter section

Protection

Ground fault monitoring 

Grid monitoring

Anti-islanding

DC reverse polarity

AC and DC short circuit and over current

AC and DC over voltage and temperature

User interface and communications

Local user interface

Analog inputs/outputs

Digital inputs/relay outputs

Fieldbus connectivity

Input (DC)

Maximum input power (PPV, max) 1)

DC voltage range, mpp (UDC, mpp)

Maximum DC voltage (Umax (DC))
Maximum DC current (Imax (DC))

Number of protected DC inputs

Output (AC)

Nominal power (PN(AC)) 3)
Maximum output power 4)

Power at cosj = 0.95 3) Nominal AC current (IN(AC)) Nominal output voltage (UN(AC)) 5)

Output frequency

Harmonic distortion, current 6)

Distribution network type 7)

Efficiency

Maximum 8)

Euro-eta 8)

Power consumption

Own consumption in operation

Standby operation consumption

External auxiliary voltage 9)

Dimensions and weight

Width/Height/Depth, mm (W/H/D)

Weight appr. 10)

    +/- 10%
     At nominal power
     Inverter side must be IT type
    Without auxiliary power consumption at min UDC
    115 V, 60 Hz optional

    For the smallest number of protected inputs. See the user manual for details.

Environmental limits

Degree of protection

Ambient temp. range (nom. ratings) 11)

Maximum ambient temperature 12)

Relative humidity, not condensing

Maximum altitude (above sea level) 13)

Maximum noise level

Maximum air flow of the inverter section

Protection

Ground fault monitoring 16)

Grid monitoring

Anti-islanding

DC reverse polarity

AC and DC short circuit and over current

AC and DC over voltage and temperature

User interface and communications

Local user interface

Analog inputs/outputs

Digital inputs/relay outputs

Fieldbus connectivity

500 kW

 

600 kWp

450 to 825 V

1100 V

1145 A

4 to 15 (+/-)

 

500 kW

600 kW

475 kW

965 A

300 V

50/60 Hz

< 3%

TN and IT

 

98.60%

98.20%

 

490 W

65 W

230 V, 50 Hz

 

2630/ 2130/ 708

1800

 

 

 

 

 

 

 

IP42

-15 to +50 °C

+55 °C

15 to 95%

4000 m

75 dBA 15)

5000 m3/h

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 local control panel

2-Jan

1-Mar

Modbus,  EtherNet

 

600 kWp

450 to 825 V

1100 V
1145 A

4 to 15 (+/-)

 

500 kW
600 kW

475 kW
965 A
300 V

50/60 Hz

< 3%

TN and IT

 

 

98.6%

98.2%

 

490 W

65 W

230 V, 50 Hz

 

2630/2130/708

1800

 

10)    For the smallest number of protected inputs. See the user manual for details.

 

IP42

-15 to +50 °C

+55 °C

15 to 95%

4000 m

75 dBA 15)

5000 m3/h

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 local control panel

1/2

3/1

Modbus,  EtherNet

 